Baxi · E125

Baxi E125 explained

E125 has appeared on your Baxi boiler. Here is what it means, what is safe to check, and when it is time to call an engineer.

Speak to an engineer Arrange a visit

E125 in plain English

E125 means water is not circulating properly through the boiler. You might see E193 first. Some causes are simple to rule out, others need a Gas Safe engineer.

Meanings vary a little between models; your manual has the definitive list. We look after homes from Cheyne Walk to Old Church Street, including plenty of basement flat by Redcliffe Square properties.

What you can check yourself

1. Release air from the radiators

Air in the system stops water circulating properly. With the heating off and the radiators cool, open the bleed screw on each radiator until a drop of water shows. Bleeding lowers the pressure, so check the gauge afterwards and top up if needed.

2. Look at the gauge

When the radiators are cold, check the gauge on the boiler fascia. The majority of boilers want around 1 to 1.5 bar when cold, but your user guide gives the figure for your model. If it reads lower than that, you can normally top it up yourself using the filling loop or filling key, which is normally underneath the boiler. Open the taps slowly, watch the needle rise, then turn them off fully once you reach the right pressure. If you find yourself topping up every week, water is escaping somewhere and that leak needs finding.

3. Try a single reset

Use the reset button on the front panel: the method varies between Baxi ranges, so check your user guide. Wait two or three minutes for it to restart. If it locks out again, do not keep pressing: repeated resets can hide a fault that needs proper attention.

Anything behind the casing, and any gas or flue work, must be left to a Gas Safe engineer. If you smell gas, leave the property and call the National Gas Emergency Service on 0800 111 999.

Likely causes

In our experience, and in the manufacturer's own guidance, the usual causes are:

When you need an engineer

If bleeding and topping up do not clear E125, the pump or a blockage needs an engineer.

If it will not clear, call 020 3507 1058 or book a visit online. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Similar codes

Questions

Can sludge cause E125?
Yes. Sludge and debris restrict flow. An engineer can clean the filter or system.
Do you repair Baxi boilers in Chelsea?
We do. Our Gas Safe engineers repair Baxi boilers across SW3 and SW10, including Fulham Road and King's Road. Ring 020 3507 1058 and quote E125.