Baxi · E119

Baxi E119 explained

E119 has appeared on your Baxi boiler. This page explains the code, the checks you can safely make and when you need us.

Speak to an engineer Arrange a visit

E119 in plain English

E119 tells you the heating system has lost pressure. Newer Baxi 600 and 800 boilers use E118 for this. Baxi's advice is to repressurise through the filling loop. Good news: this code is frequently a homeowner fix.

Always cross-check with the manual for your exact model. In older Chelsea houses the boiler is frequently in a basement or vault, so condensate is sometimes pumped up to a drain rather than running by gravity.

What you can check yourself

1. Check the pressure

Once the system has cooled down, check the gauge on the boiler fascia. The majority of boilers want around 1 to 1.5 bar when cold, but your user guide gives the figure for your model. If it reads under 1 bar, you can normally refill it yourself using the filling loop or filling key, which is normally underneath the boiler. Open the valves slowly, watch the needle rise, then shut both valves properly once you reach the right pressure. If you find yourself topping up every week, water is escaping somewhere and that leak needs finding.

2. Use the reset button, once

Press the reset button as your user guide describes: the method varies between Baxi ranges, so check your user guide. Allow a little time for the boiler to try again. If the same code comes back, stop resetting: repeated resets can hide a fault that needs proper attention.

Do not open the boiler casing, and leave anything on the gas side alone. If there is a smell of gas, call 0800 111 999 from outside.

Likely causes

Possible causes include:

When you need an engineer

If you are topping up regularly, book an engineer to find the leak.

Need a hand in Chelsea? Call 020 3507 1058 or send us the details and we will call you back. We are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Similar codes

Questions

What's the difference between Baxi E118 and E119?
Both relate to low water pressure; which one you see depends on your Baxi model.
Do you work on Baxi boilers around Chelsea?
We do. We work on Baxi boilers all over Chelsea, from Lots Road to Redcliffe Square. Call 020 3507 1058 with the code.