CE 207 in plain English
CE 207 tells you the heating system has lost pressure. Worcester says the system should normally read between 1 and 1.5 bar when cool. Newer text-display models can describe it in words. Good news: this code is frequently a homeowner fix.
Codes can differ between models, so check the fault table in your user guide too. Larger Chelsea houses frequently have zoned heating and an unvented cylinder, so a code on the boiler is not always the whole story.
What you can check yourself
1. Check the pressure
When the radiators are cold, read the gauge on the front of the boiler. The majority of boilers want roughly 1 to 1.5 bar when cold, or whatever figure your manual gives. If it reads lower than that, topping up is normally a homeowner job using the filling loop. Open the taps slowly, watch the needle rise, then shut both valves properly once you reach the right pressure. If you find yourself topping up every week, water is escaping somewhere and that leak needs finding.
2. Reset the boiler once
Follow the reset steps in your manual: on a Greenstar, hold it for around five seconds. Allow a little time for the boiler to try again. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.
Do not open the boiler casing, and leave anything on the gas side alone. Smell gas? Get outside and call 0800 111 999.
Likely causes
In our experience, and in the manufacturer's own guidance, the usual causes are:
- An expansion vessel that needs recharging
- A slow leak somewhere on the system
- The pressure relief valve discharging
- Pressure lost after bleeding radiators
When you need an engineer
If CE 207 keeps returning, water is getting out and an engineer should find where: check for damp patches and the outside relief pipe, then book an engineer.
If it will not clear, call 020 3507 1058 or book a visit online. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
Similar codes
- Vaillant F.22 (low water pressure)
- Baxi E119 (low water pressure)
- Baxi E117 (water pressure too high)
- All Worcester Bosch codes
- Boiler breakdown help in Chelsea
Questions
- Why does CE 207 keep coming back?
- Water is leaving the system, through a leak, the relief valve or because the expansion vessel has lost its charge. An engineer can trace it.
- Can you fix a Worcester Bosch boiler in Chelsea?
- Yes. We work on Worcester Bosch boilers all over Chelsea, from Draycott Place to Chelsea Harbour. Call 020 3507 1058 with the code.