Skip to main content
Gas Safe registered engineersMonday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed
Chelsea Boiler RepairChelseaBOILER REPAIR
Menu
Call 020 3507 1058

Worcester Bosch · E9 224

Worcester Bosch E9 224 explained

E9 224 has appeared on your Worcester Bosch boiler. Below: the meaning, the likely causes and the point at which to stop and call.

Speak to an engineer Arrange a visit

E9 224 in plain English

With E9 224, the flue thermostat or the high-limit thermostat has operated. Something stopped heat being carried away properly. Try the simple checks below first; if the code returns, call an engineer.

Codes can differ between models, so check the fault table in your user guide too. Larger Chelsea houses frequently have zoned heating and an unvented cylinder, so a code on the boiler is not always the whole story.

What you can check yourself

1. Start with the pressure

Once the system has cooled down, read the gauge on the front of the boiler. Most boilers want about 1 to 1.5 bar when cold, but your user guide gives the figure for your model. If it reads below 1 bar, topping up is normally a homeowner job using the filling loop, a short braided hose or a built-in key under the boiler. Open the taps slowly, watch the needle rise, then shut both valves properly once you reach the right pressure. If the pressure drops again within days, water is escaping somewhere and that is a job for an engineer.

2. Release air from the radiators

Air in the system stops water circulating properly. Once the heating has been off for a while, open the bleed screw on each radiator until a drop of water shows. Afterwards, check the pressure again, because bleeding lets water out.

3. Try a single reset

Follow the reset steps in your manual: Worcester Bosch asks you to hold it for about five seconds. Give it a couple of minutes to run through its start-up. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.

Anything behind the casing, and any gas or flue work, must be left to a Gas Safe engineer. Smell gas? Get outside and call 0800 111 999.

Likely causes

In our experience, and in the manufacturer's own guidance, the usual causes are:

When you need an engineer

One reset after checking the pressure is reasonable; if it trips again, stop and call an engineer: an engineer needs to find out why it is overheating.

Ring 020 3507 1058 with the code and your boiler's model, or use our enquiry form. Lines are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Similar codes

Questions

What causes a Worcester Bosch to overheat?
Normally poor circulation: a sticking pump, sludge, low pressure or air. Less frequently a flue or sensor fault.
Can you fix a Worcester Bosch boiler in Chelsea?
We do. Our Gas Safe engineers repair Worcester Bosch boilers across SW3 and SW10, including Redcliffe Square and King's Road. Ring 020 3507 1058 and quote E9 224.

Heating trouble in Chelsea?

Phone 020 3507 1058 or email [email protected]. Gas Safe registered engineers.

Call 020 3507 1058 Send an enquiry

Call 020 3507 1058