EA 227 in plain English
EA 227 is Worcester's most common lockout: the boiler attempted ignition and never sensed a flame. Worcester's own guidance lists the gas supply, a frozen condensate pipe and a blocked flue outlet as things to check. Try the simple checks below first; if the code returns, call an engineer.
Meanings vary a little between models; your manual has the definitive list. We look after homes from Chelsea Harbour to Old Church Street, including plenty of basement flat by Redcliffe Square properties.
What you can check yourself
1. Check gas is reaching the house
Try the gas hob, if you have one. On a prepayment meter, check the credit and any emergency credit, since a meter that has run out stops the boiler lighting. Leave the gas valve, pipes and anything behind the casing alone. If you smell gas, leave the property and call the National Gas Emergency Service on 0800 111 999.
2. Check for a frozen condensate pipe
Every modern boiler has a small plastic condensate pipe, and outdoor sections freeze in a cold snap. When it freezes the boiler frequently gurgles and stops. Only if the pipe is at ground level and easy to reach, thaw it with a hot water bottle or warm, not boiling, water from a watering can, then reset the boiler. Never climb a ladder to do this.
3. Check nothing is blocking the flue
From outside, check that nothing obvious is blocking the flue terminal, such as plants, a cover or a nest. Looking is fine; adjusting the flue is not: any damage or blockage is a job for a Gas Safe engineer.
4. Use the reset button, once
Follow the reset steps in your manual: on a Greenstar, hold it for around five seconds. Allow a little time for the boiler to try again. If it locks out again, do not keep pressing: repeated resets can hide a fault that needs proper attention.
Do not open the boiler casing, and leave anything on the gas side alone. If there is a smell of gas, call 0800 111 999 from outside.
Likely causes
Possible causes include:
- A gas valve or PCB fault
- Gas off or a prepayment meter with no credit
- A blocked flue outlet
- A worn ignition or flame-sensing electrode
- A frozen or blocked condensate pipe
When you need an engineer
If the gas is on, the condensate is clear and EA 227 still returns, call an engineer: which only a Gas Safe engineer should do.
If it will not clear, call 020 3507 1058 or book a visit online. Lines are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
Similar codes
- Worcester Bosch EA 229 (flame lost during operation)
- Vaillant F.28 (ignition failure at start-up)
- Baxi E133 (ignition or gas supply fault)
- All Worcester Bosch codes
- Boiler breakdown help in Chelsea
Questions
- Can a frozen condensate pipe cause EA 227?
- Yes. Worcester Bosch lists a frozen condensate pipe as a cause of the EA code. Thaw it safely with warm, not boiling, water if it is at ground level, then reset.