EA 229 in plain English
With EA 229, the boiler lit normally and then the flame signal dropped out. Condensate and flue problems are frequent causes. Try the simple checks below first; if the code returns, call an engineer.
Codes can differ between models, so check the fault table in your user guide too. Mansion blocks near Fulham Road may need a porter or managing agent to give access to meters and plant rooms, so it helps to have that arranged.
What you can check yourself
1. In freezing weather, check the condensate pipe
The condensate pipe is the plastic pipe that carries water from the boiler to a drain, frequently outside. If it is frozen, the boiler may gurgle and then lock out. As long as the pipe is low down and safe to reach, thaw it with a hot water bottle or warm, not boiling, water from a watering can, then reset the boiler. Leave pipes at height to an engineer.
2. Glance at the flue terminal
Check the flue terminal outside is not covered or blocked. Looking is fine; adjusting the flue is not: any damage or blockage is a job for a Gas Safe engineer.
3. Rule out the gas supply
See whether another gas appliance, such as the hob, lights. Prepayment customers should check the meter still has credit, because an empty meter looks exactly like an ignition fault to the boiler. Nothing on the gas side of the boiler is a DIY job. If you smell gas, get everyone out and call 0800 111 999.
4. Use the reset button, once
Use the reset button on the front panel: Worcester Bosch asks you to hold it for about five seconds. Allow a little time for the boiler to try again. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.
Never remove the boiler casing or touch the gas valve, gas pipes or flue. If you smell gas, leave the property and call the National Gas Emergency Service on 0800 111 999.
Likely causes
The manufacturer's fault table and day-to-day experience point to:
- Strong wind or an obstruction at the flue terminal
- A frozen or blocked condensate pipe or trap
- An interruption in the gas supply
- A worn flame-sensing electrode
When you need an engineer
If EA 229 keeps coming back, an engineer needs to check the flame-sensing circuit, condensate trap and flue: the condensate trap and flue are inside or attached to the boiler, so leave them to a Gas Safe engineer.
Need a hand in Chelsea? Call 020 3507 1058 or send us the details and we will call you back. Lines are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
Similar codes
- Worcester Bosch EA 227 (no flame detected at ignition)
- Vaillant F.29 (flame loss during operation)
- Worcester Bosch D5 (condensate pump fault (floor-standing))
- All Worcester Bosch codes
- Boiler breakdown help in Chelsea
Questions
- Does wind cause EA 229?
- It can contribute. Strong wind at the flue terminal is one possible factor, along with condensate blockages and gas supply interruptions.
- Do you repair Worcester Bosch boilers in Chelsea?
- We do. Our Gas Safe engineers repair Worcester Bosch boilers across SW3 and SW10, including Chelsea Green and Lots Road. Call 020 3507 1058 with the code.