D5 in plain English
D5 is shown by floor-standing Greenstar boilers when the condensate pump cannot clear water. Worcester also says a frozen condensate pipe can show as EA or D5, depending on the boiler. Other models may use D5 differently, so check the manual for yours. Some causes are simple to rule out, others need a Gas Safe engineer.
Always cross-check with the manual for your exact model. In older Chelsea houses the boiler is frequently in a basement or vault, so condensate is sometimes pumped up to a drain rather than running by gravity.
What you can check yourself
1. Check for a frozen condensate pipe
Every modern boiler has a small plastic condensate pipe, and outdoor sections freeze in a cold snap. If it is frozen, the boiler may gurgle and then lock out. As long as the pipe is low down and safe to reach, thaw it with a warm cloth or warm (not boiling) water, then reset the boiler. Do not try this at height.
2. Use the reset button, once
Use the reset button on the front panel: Worcester Bosch asks you to hold it for about five seconds. Allow a little time for the boiler to try again. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.
3. Get the details ready
Make a note of the code before resetting, along with the model name printed on the front or underneath, and whether it happened on heating, hot water or both. That information helps us diagnose faster.
Never remove the boiler casing or touch the gas valve, gas pipes or flue. If you smell gas, leave the property and call the National Gas Emergency Service on 0800 111 999.
Likely causes
In our experience, and in the manufacturer's own guidance, the usual causes are:
- A frozen or blocked external condensate pipe
- A failed or blocked condensate pump
- A kinked or blocked condensate hose
When you need an engineer
Repeat D5 codes mean the pump itself: it sits inside the boiler casing.
If it will not clear, call 020 3507 1058 or book a visit online. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
Similar codes
- Worcester Bosch EA 227 (no flame detected at ignition)
- Worcester Bosch EA 229 (flame lost during operation)
- Baxi E133 (ignition or gas supply fault)
- All Worcester Bosch codes
- Boiler breakdown help in Chelsea
Questions
- Does D5 mean the same on every Worcester boiler?
- No. It is documented as a condensate pump fault on floor-standing models; other models may differ, so check your manual.
- Do you work on Worcester Bosch boilers around Chelsea?
- Yes. We work on Worcester Bosch boilers all over Chelsea, from Redcliffe Square to King's Road. Call 020 3507 1058 with the code.